| Cooling air volume (m3/h) |
46.6
|
53.5
|
60.6
|
66.6
|
69.5
|
69.7
|
| Typical burner use (suction cooling) at 15 °C environmental temperature (MJ) |
5 900
|
7 300
|
7 900
|
9 500
|
9 800
|
10 300
|
| Gas consumption at typical burner use (m3/h, 34 MJ/m3) |
173.5
|
214.7
|
232.4
|
279.4
|
288.2
|
302.9
|
| Maximum burner capacity (Mwh) |
3 487
|
4 044
|
4 337
|
5 245
|
5 451
|
5 656
|
| Full-load grain capacity (t) |
28.0
|
31.4
|
35.4
|
37.9
|
40.3
|
43.6
|
| Corn 20-15% (100 °C) dry/cool |
27.5
|
33.0
|
36.7
|
42.6
|
45.1
|
48.4
|
| Corn 25-15% (100 °C) dry/cool |
16.0
|
19.1
|
21.3
|
24.7
|
26.2
|
28.1
|
| Corn 25-15% (90 °C) dry/cool |
13.7
|
16.4
|
18.3
|
21.2
|
22.5
|
24.1
|
| Corn 25-13.5% (90 °C) dry/cool |
10.6
|
12.8
|
14.2
|
16.5
|
17.5
|
18.7
|
| Corn 23.5-13.5% (90 °C) dry/cool |
12.3
|
14.7
|
16.4
|
19.1
|
20.2
|
21.6
|
| Corn 25-15% (105 °C) dry/cool |
17.6
|
21.2
|
23.6
|
27.3
|
28.9
|
31.0
|
| Corn 25-13.5% (105 °C) dry/cool |
13.7
|
16.4
|
18.3
|
21.2
|
22.5
|
24.1
|